Panasonic Domes WV-CS850/854E/CS600/CS650

The commands of the Panasonic dome system are not compatible with the commands of the KDec system.

Complete conversion is necessary. This procedure is described in the following table.

Pin assignments of connecting cable:

Number of preset positions: 40

Number of possible camera numbers: 1...96 (32 users are physically possible on the RS485 bus)

Meaning of variables:
• kkk = Enter number of dome camera, with leading zeroes if necessary
• pp = Enter preset position of selected dome camera, with leading zeroes if necessary
• vvv = Additional variable speed parameters

Panasonic functions

KDec command

MBeg

MBeg/VS

Pan right

SNkkkS-

With keys (stop = release)

  With joystick

Pan left

SNkkkS+

Tilt down

SNkkkN-

With keys

Tilt up

SNkkkN+

Pan and tilt at fast speed

SNkkk++

Press and hold key

Automatic with joystick

Pan and tilt at normal speed

SNkkk--

Release key

Automatic with joystick

Focus near

SNkkkF-

With key

Focus rocker switch

Focus far

SNkkkF+

With key

Focus stop

SNkkkF0

Release key /

Release focus

Zoom wide

SNkkkZ-

With key

Zoom rocker switch

Zoom tele

SNkkkZ+

With key

Zoom stop

SNkkkZ0

Release key /

Release zoom

Store preset

PPkkk.pp

Program preset (1 – 40)

Go to preset

SNkkk.pp

Go to preset (1 – 40)

Automatic pan between two positions

SNkkkSA

Automatic pan